====== Тест Catalyst-a 6500 ======
===== состав шасси =====
''show module''
Router#show module
Mod Ports Card Type Model Serial No.
--- ----- -------------------------------------- ------------------ -----------
1 8 CEF720 8 port 10GE with DFC WS-X6708-10GE SAL1337____
2 24 CEF720 24 port 1000mb SFP WS-X6724-SFP SAL1414____
5 5 Supervisor Engine 720 10GE (Active) VS-S720-10G SAL1505____
6 5 Supervisor Engine 720 10GE (Hot) VS-S720-10G SAL1505____
Mod MAC addresses Hw Fw Sw Status
--- ---------------------------------- ------ ------------ ------------ -------
1 0026.____.03a8 to 0026.____.03af 2.1 12.2(18r)S1 12.2(33)SXI5 Ok
2 68ef.____.dff8 to 68ef.____.e00f 4.3 12.2(18r)S1 12.2(33)SXI5 Ok
5 0024.____.6b98 to 0024.____.6b9f 4.0 8.5(4) 12.2(33)SXI5 Ok
6 0024.____.6b20 to 0024.____.6b27 4.0 8.5(4) 12.2(33)SXI5 Ok
Mod Sub-Module Model Serial Hw Status
---- --------------------------- ------------------ ----------- ------- -------
1 Distributed Forwarding Card WS-F6700-DFC3C SAL1338____ 1.4 Ok
2 Centralized Forwarding Card WS-F6700-CFC SAL1413____ 4.1 Ok
5 Policy Feature Card 3 VS-F6K-PFC3C SAL1504____ 1.1 Ok
5 MSFC3 Daughterboard VS-F6K-MSFC3 SAL1505____ 5.1 Ok
6 Policy Feature Card 3 VS-F6K-PFC3C SAL1506____ 1.1 Ok
6 MSFC3 Daughterboard VS-F6K-MSFC3 SAL1505____ 5.1 Ok
Mod Online Diag Status
---- -------------------
1 Pass
2 Pass
5 Pass
6 Pass
''show inventory''
Router#show inventory
NAME: "WS-C6506-E", DESCR: "Cisco Systems, Inc. Catalyst 6500 6-slot Chassis System"
PID: WS-C6506-E , VID: V03, SN: SAL1506____
NAME: "WS-C6K-VTT-E 1", DESCR: "VTT-E FRU 1"
PID: WS-C6K-VTT-E , VID: , SN: SMT1449____
NAME: "WS-C6K-VTT-E 2", DESCR: "VTT-E FRU 2"
PID: WS-C6K-VTT-E , VID: , SN: SMT1449____
NAME: "WS-C6K-VTT-E 3", DESCR: "VTT-E FRU 3"
PID: WS-C6K-VTT-E , VID: , SN: SMT1449____
NAME: "CLK-7600 1", DESCR: "OSR-7600 Clock FRU 1"
PID: CLK-7600 , VID: , SN: SMT1451____
NAME: "CLK-7600 2", DESCR: "OSR-7600 Clock FRU 2"
PID: CLK-7600 , VID: , SN: SMT1451____
NAME: "1", DESCR: "WS-X6708-10GE CEF720 8 port 10GE with DFC Rev. 2.1"
PID: WS-X6708-10GE , VID: V07, SN: SAL1337____
NAME: "WS-F6700-DFC3C Distributed Forwarding Card 3 sub-module of 1", DESCR: "WS-F6700-DFC3C Distributed Forwarding Card 3 Rev. 1.4"
PID: WS-F6700-DFC3C , VID: V03, SN: SAL1338____
NAME: "2", DESCR: "WS-X6724-SFP CEF720 24 port 1000mb SFP Rev. 4.3"
PID: WS-X6724-SFP , VID: V06, SN: SAL1414____
NAME: "WS-F6700-CFC Centralized Forwarding Card sub-module of 2", DESCR: "WS-F6700-CFC Centralized Forwarding Card Rev. 4.1"
PID: WS-F6700-CFC , VID: V06, SN: SAL1413____
NAME: "5", DESCR: "VS-S720-10G 5 ports Supervisor Engine 720 10GE Rev. 4.0"
PID: VS-S720-10G , VID: V06, SN: SAL1505____
NAME: "msfc sub-module of 5", DESCR: "VS-F6K-MSFC3 MSFC3 Daughterboard Rev. 5.1"
PID: VS-F6K-MSFC3 , VID: V06, SN: SAL1505____
NAME: "VS-F6K-PFC3C Policy Feature Card 3 sub-module of 5", DESCR: "VS-F6K-PFC3C Policy Feature Card 3 Rev. 1.1"
PID: VS-F6K-PFC3C , VID: V01, SN: SAL1504____
NAME: "6", DESCR: "VS-S720-10G 5 ports Supervisor Engine 720 10GE Rev. 4.0"
PID: VS-S720-10G , VID: V06, SN: SAL1505____
NAME: "msfc sub-module of 6", DESCR: "VS-F6K-MSFC3 MSFC3 Daughterboard Rev. 5.1"
PID: VS-F6K-MSFC3 , VID: V06, SN: SAL1505____
NAME: "VS-F6K-PFC3C Policy Feature Card 3 sub-module of 6", DESCR: "VS-F6K-PFC3C Policy Feature Card 3 Rev. 1.1"
PID: VS-F6K-PFC3C , VID: V01, SN: SAL1506____
NAME: "WS-C6506-E-FAN 1", DESCR: "Enhanced 6-slot Fan Tray 1"
PID: WS-C6506-E-FAN , VID: V03, SN: DCH1451____
NAME: "PS 1 WS-CAC-3000W", DESCR: "AC power supply, 3000 watt 1"
PID: WS-CAC-3000W , VID: V02, SN: AZS1452____
NAME: "PS 2 WS-CAC-3000W", DESCR: "AC power supply, 3000 watt 2"
PID: WS-CAC-3000W , VID: V02, SN: AZS1452____
===== нормальное состояние модулей, вентиляторов и БП =====
''show environment''
Router#show environment
environmental alarms:
system minor alarm on power-supply 2 power-output-fail (raised 00:56:00 ago)
backplane:
operating clock count: 2
operating VTT count: 3
fan-tray 1:
fan-tray 1 type: WS-C6506-E-FAN
fan-tray 1 mode: High-power
fan-tray 1 fan-fail: OK
VTT 1:
VTT 1 OK: OK
VTT 1 outlet temperature: 30C
VTT 2:
VTT 2 OK: OK
VTT 2 outlet temperature: 32C
VTT 3:
VTT 3 OK: OK
VTT 3 outlet temperature: 36C
clock 1:
clock 1 OK: OK, clock 1 clock-inuse: in-use
clock 2:
clock 2 OK: OK, clock 2 clock-inuse: not-in-use
power-supply 1:
power-supply 1 fan-fail: OK
power-supply 1 power-input: AC high
power-supply 1 power-output-mode: high
power-supply 1 power-output-fail: OK
power-supply 2:
power-supply 2 power-output-fail: failed
module 1:
module 1 power-output-fail: OK
module 1 outlet temperature: 45C
module 1 inlet temperature: 35C
module 1 aux-1 temperature: 44C
module 1 aux-2 temperature: 40C
module 1 asic-1 temperature: 70C
module 1 asic-2 temperature: 67C
module 1 EARL outlet temperature: 38C
module 1 EARL inlet temperature: 34C
module 2:
module 2 power-output-fail: OK
module 2 outlet temperature: 32C
module 2 inlet temperature: 32C
module 2 device-1 temperature: 30C
module 2 device-2 temperature: 34C
module 5:
module 5 power-output-fail: OK
module 5 outlet temperature: 40C
module 5 inlet temperature: 30C
module 5 device-1 temperature: 35C
module 5 device-2 temperature: 37C
module 5 asic-1 temperature: 59C
module 5 asic-3 temperature: 43C
module 5 asic-4 temperature: 54C
module 5 RP outlet temperature: 33C
module 5 RP inlet temperature: 33C
module 5 EARL outlet temperature: 35C
module 5 EARL inlet temperature: 30C
module 6:
module 6 power-output-fail: OK
module 6 outlet temperature: 43C
module 6 inlet temperature: 30C
module 6 device-1 temperature: 36C
module 6 device-2 temperature: 38C
module 6 asic-1 temperature: 59C
module 6 asic-3 temperature: 43C
module 6 asic-4 temperature: 55C
module 6 RP outlet temperature: 34C
module 6 RP inlet temperature: 33C
module 6 EARL outlet temperature: 35C
module 6 EARL inlet temperature: 30C
chassis connector rating: 1302.00 Watts (31.00 Amps @ 42V)
chassis auxiliary connector rating: 2016.00 Watts (48.00 Amps @ 42V)
module 1
module 1 connector rating: 2016.00 Watts (48.00 Amps @ 42V)
module 1 power consumption: 444.36 Watts (10.58 Amps @ 42V)
module 2
module 2 connector rating: 2016.00 Watts (48.00 Amps @ 42V)
module 2 power consumption: 125.16 Watts ( 2.98 Amps @ 42V)
module 5
module 5 connector rating: 1260.00 Watts (30.00 Amps @ 42V)
module 5 power consumption: 338.10 Watts ( 8.05 Amps @ 42V)
module 6
module 6 connector rating: 1260.00 Watts (30.00 Amps @ 42V)
module 6 power consumption: 338.10 Watts ( 8.05 Amps @ 42V)
chassis per slot cooling capacity: 94 cfm
ambient temperature: < 55C
module 1 cooling requirement: 84 cfm
module 2 cooling requirement: 70 cfm
module 5 cooling requirement: 35 cfm
module 6 cooling requirement: 35 cfm
===== Диагностические тесты =====
Запустить минимальный тест: \\
''diagnostic start module test minimal''
Посмотреть результаты последних проверок: \\
''show diagnostic result module all''
Router# show diagnostic result module all
Current bootup diagnostic level: minimal
Module 1: CEF720 8 port 10GE with DFC SerialNo : SAL1337Y95E
Overall Diagnostic Result for Module 1 : PASS
Diagnostic level at card bootup: minimal
Test results: (. = Pass, F = Fail, U = Untested)
1) TestOBFL ------------------------> .
2) TestFabricCh0Health -------------> .
3) TestFabricCh1Health -------------> .
4) TestTransceiverIntegrity:
Port 1 2 3 4 5 6 7 8
----------------------------
U U U U U U U U
5) TestLoopback:
Port 1 2 3 4 5 6 7 8
----------------------------
. . . . . . . .
6) TestScratchRegister -------------> .
7) TestSynchedFabChannel -----------> .
8) TestNewIndexLearn ---------------> U
9) TestDontConditonalLearn ---------> U
10) TestCapture ---------------------> U
11) TestTrap ------------------------> U
12) TestMacNotification -------------> .
13) TestFibDevices ------------------> .
14) TestIPv4FibShortcut -------------> .
15) TestIPv6FibShortcut -------------> .
16) TestNATFibShortcut --------------> .
17) TestMPLSFibShortcut -------------> .
18) TestL3Capture -------------------> U
19) TestL3VlanMet -------------------> .
20) TestIngressSpan -----------------> .
21) TestEgressSpan ------------------> .
22) TestAclPermit -------------------> .
23) TestAclDeny ---------------------> .
24) TestQos -------------------------> .
25) TestNetflowShortcut -------------> .
26) TestFibTcamSSRAM ----------------> U
27) TestAsicMemory ------------------> U
28) TestEobcStressPing --------------> U
29) TestFirmwareDiagStatus ----------> .
30) TestAsicSync --------------------> .
31) TestUnusedPortLoopback:
Port 1 2 3 4 5 6 7 8
----------------------------
. . . . . . . .
32) TestErrorCounterMonitor ---------> .
33) TestPortTxMonitoring:
Port 1 2 3 4 5 6 7 8
----------------------------
U U U U U U U U
34) TestLtlFpoeMemoryConsistency ----> .
35) TestRwEngineOverSubscription ----> U
36) TestEARLInternalTables ----------> .
Module 2: CEF720 24 port 1000mb SFP SerialNo : SAL1414EMLH
Overall Diagnostic Result for Module 2 : PASS
Diagnostic level at card bootup: minimal
Test results: (. = Pass, F = Fail, U = Untested)
1) TestTransceiverIntegrity:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
----------------------------------------------------------------------------
U U U U U U U U U U U U U U U U U U U U U U U U
2) TestLoopback:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
----------------------------------------------------------------------------
. . . . . . . . . . . . . . . . . . . . . . . .
3) TestTxPathMonitoring ------------> .
4) TestSynchedFabChannel -----------> .
5) TestL3VlanMet -------------------> .
6) TestIngressSpan -----------------> .
7) TestEgressSpan ------------------> .
8) TestAsicMemory ------------------> U
9) TestEobcStressPing --------------> U
10) TestFirmwareDiagStatus ----------> .
11) TestAsicSync --------------------> .
12) TestUnusedPortLoopback:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
----------------------------------------------------------------------------
U U U U U U U U U U U . U U U U U U U U U U U .
13) TestOBFL ------------------------> .
14) TestErrorCounterMonitor ---------> .
15) TestPortTxMonitoring:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
----------------------------------------------------------------------------
U U U U U U U U U U U U U U U U U U U U U U U U
16) TestLtlFpoeMemoryConsistency ----> .
17) TestRwEngineOverSubscription ----> U
Module 5: Supervisor Engine 720 10GE (Active) SerialNo : SAL150569YY
Overall Diagnostic Result for Module 5 : PASS
Diagnostic level at card bootup: minimal
Test results: (. = Pass, F = Fail, U = Untested)
1) TestScratchRegister -------------> .
2) TestSPRPInbandPing --------------> .
3) TestTransceiverIntegrity:
Port 1 2 3 4 5
-------------------
U U U U U
4) TestActiveToStandbyLoopback:
Port 1 2 3 4 5
-------------------
U U U U U
5) TestLoopback:
Port 1 2 3 4 5
-------------------
. . . . .
6) TestNewIndexLearn ---------------> .
7) TestDontConditionalLearn --------> .
8) TestBadBpduTrap -----------------> .
9) TestMatchCapture ----------------> .
10) TestProtocolMatchChannel --------> .
11) TestMacNotification -------------> U
12) TestFibDevices ------------------> .
13) TestIPv4FibShortcut -------------> .
14) TestL3Capture2 ------------------> .
15) TestIPv6FibShortcut -------------> .
16) TestMPLSFibShortcut -------------> .
17) TestNATFibShortcut --------------> .
18) TestNetflowShortcut -------------> .
19) TestAclPermit -------------------> .
20) TestAclDeny ---------------------> .
21) TestQoSTcam ---------------------> .
22) TestL3VlanMet -------------------> .
23) TestIngressSpan -----------------> .
24) TestEgressSpan ------------------> .
25) TestFabricInternalSnake ---------> .
26) TestFabricExternalSnake ---------> .
27) TestTrafficStress ---------------> U
28) TestFibTcamSSRAM ----------------> U
29) TestAsicMemory ------------------> U
30) TestAclQosTcam ------------------> U
31) TestNetflowTcam -----------------> U
32) ScheduleSwitchover --------------> U
33) TestFirmwareDiagStatus ----------> .
34) TestAsicSync --------------------> .
35) TestUnusedPortLoopback:
Port 1 2 3 4 5
-------------------
U U U . .
36) TestErrorCounterMonitor ---------> .
37) TestFabricFlowControlStatus -----> U
38) TestPortTxMonitoring:
Port 1 2 3 4 5
-------------------
U U U U U
39) TestSpuriousIsrDetection --------> U
40) TestOBFL ------------------------> .
41) TestCFRW:
Device 1
---------
U
42) TestLtlFpoeMemoryConsistency ----> .
43) TestRwEngineOverSubscription ----> U
44) TestEARLInternalTables ----------> .
Module 6: Supervisor Engine 720 10GE (Hot) SerialNo : SAL150569VY
Overall Diagnostic Result for Module 6 : PASS
Diagnostic level at card bootup: minimal
Test results: (. = Pass, F = Fail, U = Untested)
1) TestScratchRegister -------------> .
2) TestSPRPInbandPing --------------> .
3) TestTransceiverIntegrity:
Port 1 2 3 4 5
-------------------
U U U U U
4) TestActiveToStandbyLoopback:
Port 1 2 3 4 5
-------------------
. . . . .
5) TestLoopback:
Port 1 2 3 4 5
-------------------
. . . . .
6) TestNewIndexLearn ---------------> .
7) TestDontConditionalLearn --------> .
8) TestBadBpduTrap -----------------> .
9) TestMatchCapture ----------------> .
10) TestProtocolMatchChannel --------> .
11) TestMacNotification -------------> .
12) TestFibDevices ------------------> .
13) TestIPv4FibShortcut -------------> .
14) TestL3Capture2 ------------------> .
15) TestIPv6FibShortcut -------------> .
16) TestMPLSFibShortcut -------------> .
17) TestNATFibShortcut --------------> .
18) TestNetflowShortcut -------------> .
19) TestAclPermit -------------------> .
20) TestAclDeny ---------------------> .
21) TestQoSTcam ---------------------> .
22) TestL3VlanMet -------------------> .
23) TestIngressSpan -----------------> .
24) TestEgressSpan ------------------> .
25) TestFabricInternalSnake ---------> .
26) TestFabricExternalSnake ---------> U
27) TestTrafficStress ---------------> U
28) TestFibTcamSSRAM ----------------> U
29) TestAsicMemory ------------------> U
30) TestAclQosTcam ------------------> U
31) TestNetflowTcam -----------------> U
32) ScheduleSwitchover --------------> U
33) TestFirmwareDiagStatus ----------> .
34) TestAsicSync --------------------> .
35) TestUnusedPortLoopback:
Port 1 2 3 4 5
-------------------
U U U . .
36) TestErrorCounterMonitor ---------> .
37) TestFabricFlowControlStatus -----> U
38) TestPortTxMonitoring:
Port 1 2 3 4 5
-------------------
U U U U U
39) TestSpuriousIsrDetection --------> U
40) TestOBFL ------------------------> .
41) TestCFRW:
Device 1
---------
U
42) TestLtlFpoeMemoryConsistency ----> .
43) TestRwEngineOverSubscription ----> U
44) TestEARLInternalTables ----------> .
===== Файлы на флеше =====
Router#sh file systems
File Systems:
Size(b) Free(b) Type Flags Prefixes
- - opaque ro flexwan-fpd:
- - opaque rw system:
- - opaque rw tmpsys:
65536000 65536000 flash rw bootflash:
- - disk rw disk0:
* 1024557056 889913344 disk rw sup-bootdisk: sup-bootflash:#
57779906 0 opaque ro sup-microcode:
0 745032604 opaque wo sup-image:
129004 128448 nvram rw const_nvram:
1964024 1959745 nvram rw nvram:
- - opaque rw null:
- - opaque ro tar:
- - network rw tftp:
- - opaque wo syslog:
- - network rw rcp:
- - network rw http:
- - network rw ftp:
- - opaque ro cns:
1964024 1959745 nvram rw slavenvram:
129004 128448 nvram rw slaveconst_nvram:
- - disk rw slavedisk0:
1024557056 889913344 disk rw slavesup-bootdisk: slavesup-bootflash:#
65536000 65536000 flash rw slavebootflash:
- - nvram rw slavercsf:
- - opaque rw slavesystem:
15990784 15990784 flash rw dfc#2-bootflash:
15990784 15990784 flash rw dfc#1-bootflash:
- - opaque rw revrcsf:
Router#show sup-bootdisk:
-#- --length-- -----date/time------ path
1 67530468 Feb 9 2011 13:39:52 +00:00 s72033-ipbase-mz.122-33.SXI5.bin
2 33554432 Feb 9 2011 13:38:42 +00:00 sea_console.dat
3 33554432 Feb 9 2011 16:19:00 +00:00 sea_log.dat
889913344 bytes available (134643712 bytes used)
Router#show slavesup-bootdisk:
-#- --length-- -----date/time------ path
1 67530468 Feb 9 2011 12:56:02 +00:00 s72033-ipbase-mz.122-33.SXI5.bin
2 33554432 Feb 9 2011 12:55:06 +00:00 sea_console.dat
3 33554432 Feb 9 2011 15:29:58 +00:00 sea_log.dat
889913344 bytes available (134643712 bytes used)